MINI-SPLIT SYSTEM CH-S24FTX5

winner-series
winner-series
outdoor_2
control_4

Description

  • Efficient temperature range from -15 °C to +43 °C;
  • Full match with the current Directive from 1.01.13 European Union (Energy related Products) № 626/2011/EU for domestic heat pumps and air conditioners SEER A++ SCOP A++;
  • Energy Efficiency Class A++. Energy-saving configuration of A++ Class Energy Efficiency type — Generation III;
  • Advanced inverter technology I-Action;
  • COLD PLAZMA function;
  • I FEEL function;
  • Eco heating operation;
  • Energy saving cooling operation mode;
  • New premium level remote control with ergonomic design and nighttime backlight;
  • Sophisticated software to optimize air conditioner operation within wide range of compressor frequency rotations;
  • Multispeed fan;
  • Wide air flow distribution;
  • Autorestart;
  • Outdoor unit block system from frozing;
  • 24H timer;
  • Cold air flow block system during heating operation;
  • Blue Fin coating;
  • Operation under Sleep mode;
  • Auto dehumidifying;
  • Color display;
  • Compressor block system;
  • Operation from low outside ambient temperature.

Power consumption for heating : 1,945 kW
Power consumption for cooling : 1,875 kW
Performance, cooling : 6,7 kW
Performance, heating : 7,25 kW
Type of refrigerant : R410A
Indoor / outdoor unit weight : 17/53 kg
Source of electiricty : ~220-240V/50Hz/1F
Air flow : 850/950/1000/1100 m³/hr
Indoor unit noise level (min/avg/max) : 30/33/40/45 dB(A)
Indoor unit dimensions (width/height/depth) : 1078X246X325 mm
Outdoor unit dimensions (width/height/depth) : 963X396X700 mm
Outdoor unit noise level (min/avg/max) : 51 dB(A)
Work temperature range/cooling: -24...+43 °C
Work temperature range/heating: -15...+24 °C
Maximum height discontinuity highway : 10 m
Maximum length highway : 25 m
SEER - Seasonal coefficient of performance (cooling) : 6,3(A++)
SCOP - seasonal coefficient of performance (heating) : 4,6(A++)