| cooling | 6,45 (1,40-7,00) kW |
|---|---|
| Heating | 6,60 (1,50-7,90) kW |
| Capacity | Cold | kW | 6,45 (1,40-7,00) |
| Warm | kW | 6,60 (1,50-7,90) | |
| Electric power supply | ~220-240V/50Hz/1Ph | ||
| Rated input | Cold | kW | 1,50 (0,38-2,80) |
| Warm | kW | 1,425 (0,40-2,50) | |
| Energy performance EER | Cold | kW/kW | 4,30 |
| Energy performance COP | Warm | kW/kW | 4,63 |
| SEER - Seasonal coefficient of performance | Cooling | 6,4(А++) | |
| SCOP - seasonal coefficient of performance | Heating | 4,8(А++) | |
| Air productive capacity | m³/h | 1150/1050/950/850 | |
| Sound-pressure level | Indoor unit | dB(A) | 48/45/42/28 |
| Outdoor unit | dB(A) | 60 | |
| Type of refrigerant coolant | R410А | ||
| Dimensions | Indoor unit | mm | 1081х327х248 |
| Outdoor unit | mm | 960х700х396 | |
| Weight | Indoor unit | kg | 16,5 |
| Outdoor | kg | 43,5 | |
| Compressor type | rotor | ||
| Drainage | l/h | 2,00 | |
| Operational temperature range | Cooling | °C | +18 ... +48 |
| Heating | °C | -23 ... +24 | |
| Gas charge volume | kg | 1,45 | |
| Liquid pipeline diameter | mm/inch | 6,38/1/4" | |
| Gas pipeline diameter | mm/inch | 16,7/5/8" | |
| Maximum pipeline level difference | m | 10 | |
| Pipeline maximum length | m | 25 | |
| Distance between the bolts of the outdoor unit fastening | mm | 560 | |