| Model | _ | _ | CH-HP12SIRM5 (9kw electric heater) | 
| Power Supply | _ | _ | 400VAC, 50HZ | 
| Capacity*1 | Cooling (floor cooling) | kW | 12.20 | 
| Capacity*1 | Heating (floor heating) | kW | 11.70 | 
| Power Input*1 | Cooling (floor cooling) | kW | 3.14 | 
| Power Input*1 | Heating (floor heating) | kW | 2.39 | 
| EER*1 (floor cooling) | _ | W/W | 3.89 | 
| COP*1 (floor heating) | _ | W/W | 4.91 | 
| Capacity*2 | Cooling (For fan coil) | kW | 11.10 | 
| Capacity*2 | Heating (Fan coil or Radiator) | kW | 12.50 | 
| Power Input*2 | Cooling (For fan coil) | kW | 3.83 | 
| Power Input*2 | Heating (Fan coil or Radiator) | kW | 3.25 | 
| EER*1 (for Fan coil) | _ | W/W | 2.90 | 
| COP*1 (Fan coil or Radiator) | _ | W/W | 3.84 | 
| Maximum current | Heating | A | 9.10 | 
| Cooling | A | 7.40 | |
| Operating electrical current | Heating | A | 4.70 | 
| Operating electrical current | Cooling | A | 4.00 | 
| Starting current | Heating | A | 1.90 | 
| Starting current | Cooling | A | 1.90 | 
| Water flow rate | Rated | m³/h | 2.06 | 
| Water flow rate | Minimum | m³/h | 1.22 | 
| Sound pressure level | Cooling | dB(A) | 57.0 | 
| Sound pressure level | Heating | dB(A) | 55.7 | 
| Outdoor dimensions (W×D×H) | Outline | mm | 993×385×960 | 
| Outdoor dimensions (W×D×H) | Packaged | mm | 1153×478×1110 | 
| Indoor dimensions (W×D×H) | Outline | mm | 429×268×935 | 
| Indoor dimensions (W×D×H) | Packaged | mm | 1138×533×340 | 
| Net weight/ Gross weight | Indoor | kg | 51/59 | 
| Net weight/ Gross weight | Outdoor | kg | 102/112 | 
| Connecting pipe | Gas | inch(mm) | 5/8(16) | 
| Connecting pipe | Liquid | inch(mm) | 3/8(9.52) | 
| Refrigerant charge volume | kg | 1.84 | |
| Operating temperature range | Cooling | °C | -15~48 | 
| Operating temperature range | Heating | °C | -30~35 | 
| Operating temperature range | Water Heating | °C | -30~45 |